Model No.︰SY8126
Brand Name︰SONGYANG
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc
1 Introduction
SY8126 single phase Energy Meter Test Equipment is a new generation, high precision, energy meter calibration equipment. It uses the international’s most advanced technology and components available in 90 decade. The equipment works under the control of keyboard or remote computer.
2 Function
3 Technical Specification
|
|
|||||||||||||||||
|
SY3803: Wide current reference standard energy meter,
Accuracy: Class 0.02 / 0.05 / 0.1
Primary & Secondary Voltage Ratio: 1:1
No of secondary outputs: 60 / 48 / 24 / 12 / 6
Range of secondary burden: 30VA per winding
Error: < + 0.01%, + 0.3 min, when each secondary load is the same
Insulation performance: AC voltage 3kV for 1 minute (between primary and secondary)
Voltage range: 30V ~ 300V (Phase – Neutral)
Measurement error: 0.02% / 0.05%RG (when connect reference standard)
Drift per year: 0.05%
Stability: 50ppm/h / 100ppm/h (with integration time of 60seconds)
Capacity: 2000VA / 1500VA / 750VA / 250VA
Current range: 10mA ~ 120A (Option 20mA ~ 200A)
Measurement error: 0.02% / 0.05%RD (50mA~120A)
0.02% / 0.05%RG (10mA~50mA) (when connect reference standard)
Drift per year: 0.05%
Stability: 50ppm/h / 100ppm/h (with integration time of 60seconds)
Capacity: 2500VA / 2000VA / 1000VA / 500VA
Power factor range: -1.000 - 0 - 1.000
Measurement error: 0.05%RG, PF 0.5-1 (when connect reference standard)
Drift per year: 0.05%
Frequency range: 45 ~ 65Hz (40Hz to 70Hz is optional)
Measurement error: 0.02%
Drift per year: 0.005%
2-21 harmonic wave, Contents of Harmonic Wave (Voltage &Current< 40%)
The maximum power consumption: 3x 5000VA
Storage range: -200C ~ 550C
Operating range: 50C ~ 400C
Specified range: 100C ~ 300C
Temperature co-efficient: 0.01% / 0C
Relative Humidity: ≤85%
Application︰ Double channels energy Meter Test Equipment with MSVT, Used for 2 element single phase mechanical and electric meter, Number of meter position : 3-60 Single Phase Meter Test System.