Functions and Features︰
● The bench accord with the standard of "IEC 60736:1982 testing equipment for electrical energy meter", "IEC 62053"
● Close-link and ordinary calibration both can be used, ordinary calibration can be used to test single/three phase active and reactive energy meter (up to 0.5 class),close-link calibration can be used to test single/three phase active and reactive energy meter (up to 1 class)
● The bench can test the converted quantity which is caused by negative phase, voltage unbalance, harmonic wave and so on
● The bench can auto-calibrate starting, no load, basic error and calibration tolerance and 24h deflection.
● Close-link calibration is using insulate current transformer and suitable for close-link energy meter.
● The bench is using the standard power meter with comparison technology to offer the test the error of energy meters.
● The bench is using the error processor system to calculate the error of each energy meter by the sub-error system which can be connected by the internal RS485.
● The same specification but different constant energy meter can be tested at one time.
● For the installed pick-up equipment, can offer 3 ranges adjustment. It is also can be accepted the signal for both round-style energy meter and digital LED energy meter.
● The bench can choose to operate by keyboard or PC which is very convenient. The working status of bench can be seen very clear and easy operation.
● The bench is using the testing software complied with WINDOWS98/2000/XP which can auto-testing different energy meters.
● The software can realize the data from energy meter for statistics, search and management. It also can connect with on-line management for up load the data
● The energy meter hanging rack is made by Aluminum compound. The whole device configuration is a reasonable design and nice outfit.
Technical Parameters:︰
1. Accuracy class: 0.2 class (close-link calibration, the range of current: 0.25A-100A)
0.05/0.1 class (ordinary calibration)
2. Standard power testing equipment:
Three phase multi-functions precision power reference meter
Accuracy class:0.05/0.1 class
3. Isolated current transformer equipment:
Insulate current inductance
Accuracy class: 0.1 (PF=0.5C-1-0.5L, 0.25-100A)
Primary current: 3x0.25-100A secondary current: 3x0.25-100A
Output power: 30VA (MAX, 100A)
4. Output voltage: 3x57.7/100/220/380V; range: 0-120%
Fine adjustment: 0.01%
5. Output current: 3×0.1-100A
Fine adjustment: 0.0001A (min)
6. Range of phase: 0-360' fine adjustment: 0.1'
7. Frequency: 45Hz-65Hz; fine adjustment: 0.01Hz
8. Waveform distortion coefficient: voltage/ current < 0.5%
9. Output stability of voltage, current, power: <0.05% (180S)
10. Output capacity (each phase): current: 900VA (120A), voltage: 300VA (8 meters)
Load: capacitance, resistance, inductance (<=4uF)
11. Harmonic wave output:
2-21 sub-harmonic wave contents<=40%
3, 5, 7 sub-harmonic wave coupling, total content<=40%
Phase angle control (odd sub-harmonic wave)
Wave group control (sub-harmonic wave)
12. Starting current output: 1mA (min), accuracy: 5%, starting power: accuracy 5%
13. Numbers of calibrated energy meter: 8 (16 on requested)
14. Testing function: Basic error test; no load test; starting test; calibration tolerance test; harmonic test
15. Input power: 3x220V/380V (Y) +- 10%, 50Hz; max. Power consumption: 1800VA (8 meters)
16. Dimension:
Type of bench |
Meters |
Number |
Number of row |
Size |
Integration |
8
16 |
1
1 |
Single
Double |
2400×850×1650 mm
2400×850×1920 mm |
Fission |
8
16 |
1
1 |
Single
Double |
2400×600×1650 mm
2400×600×1920 mm |
Console: 600×800×1920 mm |